The short version
- A roof is a system, not a shingle. Deck, underlayment, flashing, fasteners, covering and ventilation all have their own code rules. A great shingle over reused, rusted flashing still leaks.
- Slope decides what is even allowed. Asphalt shingles need at least 2 in 12, tile 2.5 in 12, wood 3 in 12 and slate 4 in 12 under the 2024 IRC. Low porches and patio covers often rule out the "pretty" options.
- Weight decides what is practical. Clay and concrete tile weigh several hundred pounds per 100 square feet. Moving from shingles to tile usually means an engineer checks the framing first.
- Read the labels. Shingle bundles must show a wind class (ASTM D7158 or D3161), underlayment must show its ASTM standard, and impact claims should point to a test (UL 2218 class or an IBHS rating).
- Hail here can beat the lab test. In 20 years of NOAA reports, 20% of the days with 1-inch-plus hail near our five towns had a largest stone of 2 inches or more, the steel-ball size used for UL 2218 Class 4.
A note on rules: the City of Celina's Building Services page lists the 2024 International Codes, including the International Residential Code (IRC), as adopted effective January 2026. The code sections quoted below come from IRC Chapter 9 (text via UpCodes; official reference: ICC Chapter 9). Local amendments and the City inspector decide what passes on a given house, and the manufacturer's instructions apply on top of the code. Melissa, Anna, Princeton and Prosper run their own permit offices; see the service area pages.
Your roof, layer by layer
Most Celina homes are steep-slope roofs on wood decking. From the inside out, here is what sits on the rafters or trusses and what the 2024 IRC says about each layer:
| Layer | What it does | Code basics (2024 IRC) | What to ask |
|---|---|---|---|
| Roof deck (sheathing) | The structural surface everything is nailed to | Asphalt shingles must go on wood structural panels or solid lumber sheathing (R905.2.1). The structure must carry the new covering's weight (R908.2). | How will soft or delaminated decking be found and priced per sheet? |
| Underlayment | Backup water barrier under the covering | Must meet a listed ASTM standard and carry a label (R905.1.1). Double layer on 2:12 to 4:12 shingle roofs (R905.2.2). | Which product and ASTM standard? Felt or synthetic? |
| Ice barrier / self-adhered membrane | Seals around nails at eaves and valleys | Code requires an ice barrier only where January's average daily temperature is 25°F or less (R905.1.2). | Where will self-adhered membrane go anyway (valleys, eaves, penetrations)? |
| Drip edge and flashing | Seals edges, walls, valleys, chimneys | Drip edge at eaves and rakes; 0.019-inch minimum metal flashing; cricket behind wide chimneys (R903.2, R905.2.8). | Which metal is new and which is reused? |
| Starter, field and ridge | The visible covering | Shingles meet ASTM D3462 and carry a wind-class label (R905.2.4, R905.2.4.1). | Exact product, color, wind class, impact class or IBHS rating? |
| Fasteners | Hold everything down in wind | 12-gauge, 3/8-inch-head roofing nails, 3/4 inch into the deck, at least four per strip shingle (R905.2.5, R905.2.6). | Standard or high-wind nailing pattern? |
| Ventilation | Moves heat and moisture out of the attic | Covered in IRC R806; see our attic ventilation guide. | Intake and exhaust net free area in square inches? |
Every roof covering the code allows, compared
The 2024 IRC Chapter 9 has a section for each steep-slope covering. The table pulls the rules that matter most to a Celina homeowner. Costs are not listed here on purpose; see the roof replacement cost guide and the shingle vs. metal comparison for sourced Dallas-area numbers.
| Covering | Minimum slope | Product standard / label | Weight and structure | Celina notes |
|---|---|---|---|---|
| Asphalt shingles (3-tab, architectural, impact-rated) | 2:12; double underlayment up to 4:12 (R905.2.2) | ASTM D3462; wind class D7158 or D3161 on the bundle | Lightest common option; no structural change on most homes | The default choice on most homes; HOA color rules still apply |
| Metal shingles | 3:12 (R905.4.2) | Listed product; compatible fasteners | Light | Can be dented by hail; check cosmetic-damage terms in your policy |
| Metal panels (standing seam, lapped) | Standing seam 1/4:12; lapped 3:12, or 1/2:12 with lap sealant (R905.10.2) | Coatings such as G90 or AZ50 (Table R905.10.3(2)) | Light; complete standing-seam systems may go over an existing roof (R908.4) | Compare in depth on our metal vs. shingle page |
| Clay tile | 2.5:12; double underlayment up to 4:12 (R905.3.2) | ASTM C1167 (R905.3.4) | About 600–650 lb per 100 sq ft (InterNACHI); engineer check when converting | HOA approval usually needed for a change in look |
| Concrete tile | 2.5:12; double underlayment up to 4:12 | ASTM C1492 (R905.3.5) | About 800–1,100 lb per 100 sq ft; lightweight 500–800 (InterNACHI) | Heaviest common option; nails at least 11-gauge (R905.3.7) |
| Slate and slate-type shingles | 4:12 (R905.6.2) | Wind class to ASTM D3161 (R905.6.5) | Heavy; two fasteners per slate (R905.6.6) | Damaged slate may not be reinstalled (R908.5) |
| Wood shingles and shakes | 3:12 (R905.7.2, R905.8.2) | Grade tables R905.7.4 / R905.8.5; label required | Moderate | Fire classification matters where the roof edge is within 3 ft of a lot line (R902.1); treated products must be labeled (R902.2) |
| Solar shingles / BIPV roof panels | See R905.16 and the product listing | Fire classification to UL 7103 (R902.3) | Per product | Rooftop panels mounted over shingles follow separate rules (R902.4) |
Fire ratings deserve a word. Under R902.1, a rated Class A, B or C roof assembly is required where a jurisdiction requires it or where the edge of the roof deck is less than 3 feet from a lot line, tested to ASTM E108 or UL 790. Clay or concrete tile, slate and metal on a noncombustible deck count as Class A by default; on the wood decks most houses have, the rating comes from the product's listed assembly. Ask for it in writing.
Architectural asphalt shingles
The most common choice. Modern laminated shingles offer better wind ratings and aesthetics than older three-tabs. Look for warranties that match installation quality and ventilation requirements. For how long they typically last here, and why heat and hail shorten the published ranges, see shingle lifespan in North Texas heat.
Two code basics worth knowing: asphalt shingles may only go on roofs with a slope of at least 2 in 12, and roofs between 2:12 and 4:12 need a double layer of underlayment (IRC R905.2.2). Shingle packaging must carry a wind-resistance classification label under ASTM D7158 or D3161 (R905.2.4.1).
Reading the wind class on the bundle
Table R905.2.4.1 ties the label on the bundle to the design wind speed your house is built for:
| Ultimate design wind speed (Vult) | ASTM D7158 class allowed | ASTM D3161 class allowed |
|---|---|---|
| Up to 110 mph | D, G or H | A, D or F |
| 116 mph | D, G or H | A, D or F |
| 129 mph | G or H | A, D or F |
| 142–155 mph | G or H | F |
| 168–194 mph | H | F |
The design wind speed for your address comes from the code's wind map and any local amendment, so ask the roofer and the permit office which value they use. If you want more margin than the minimum, the IBHS FORTIFIED Roof standard asks for the top classes (D3161 Class F or D7158 Class H), plus a sealed roof deck, ring-shank deck nails and a stronger edge. Our roof replacement page explains FORTIFIED in more detail, and wind damage on Celina roofs covers what wind actually does to shingles.
Impact-resistant shingles and how big Celina hail gets
Class 4 impact-rated products can improve hail resilience and may qualify for insurance discounts with some carriers — confirm with your agent. Cost is higher up front; long-term value depends on your risk and policy. More detail: impact-resistant shingles and Texas insurance.
It helps to know what size stones actually fall here. The table counts days with a 1-inch-or-larger hail report within 10 miles of each town center (NOAA Storm Prediction Center severe weather reports, 2005–2024), sorted by the largest stone reported that day:
| Town | Days with 1"+ hail | Largest 1–1.74" | 1.75–1.99" (golf ball) | 2–2.74" | 2.75"+ |
|---|---|---|---|---|---|
| Celina | 34 | 23 | 5 | 3 | 3 |
| Prosper | 49 | 27 | 6 | 11 | 5 |
| Anna | 33 | 22 | 9 | 2 | 0 |
| Melissa | 46 | 28 | 11 | 5 | 2 |
| Princeton | 39 | 20 | 9 | 8 | 2 |
| Five towns | 201 | 120 | 40 | 29 | 12 |
On 41 of those 201 town-days (20%), the largest stone was 2 inches or more. That matters for materials because UL 2218 Class 4, the top class on most shingle bundles, uses a 2-inch steel ball (per a 2020 IIBEC Interface article), and FORTIFIED describes its hail-rated shingles as better protecting homes from hail up to 2 inches. Celina alone logged 34 days with 1-inch-plus hail nearby. These are report counts near each town center, not proof that hail hit your street; dates and seasons are in Celina hail history.
Not all "impact-resistant" shingles perform the same. In its November 2025 update, IBHS tested 24 impact-resistant shingle products bought from retail outlets, covering about 95% of the impact-resistant shingles sold each year. Most rated Good, none rated Excellent overall, and IBHS says it does not recommend Marginal or Poor products in areas that get hail. You can look up a specific product in the IBHS Hail Impact-Resistant Shingle Ratings. Ask the roofer for the exact product name, then check it there.
Metal roofing
Standing seam and other metal systems excel in longevity and heat reflection for the right designs. Noise, expansion details, and installer skill matter. Not every HOA allows every metal profile; check our HOA roofing guide before you fall in love with one.
- Slope limits. Metal roof shingles can't go below 3:12 (R905.4.2). Standing-seam panels can go as low as 1/4:12, and lapped, non-soldered panels need 3:12 without lap sealant or 1/2:12 with it (R905.10.2).
- Corrosion coatings. The code lists minimum coatings for steel panels, such as G90 galvanizing or AZ50 aluminum-zinc (often sold as Galvalume) (Table R905.10.3(2)).
- Matching fasteners. Without manufacturer instructions, the code calls for galvanized fasteners on steel roofs and copper, brass, bronze or 300-series stainless on copper roofs; stainless is acceptable on metal roofs generally (R905.10.4). The broader rule is that roofing materials must be compatible with each other (R904.2). Mixing the wrong metals is how fasteners and flashing corrode early.
- Hail and insurance. The Texas Department of Insurance's metal roofs and home insurance post says metal can still dent from hail, that some insurers' metal-roof discounts come with an exclusion for cosmetic damage, and that terms can change at renewal.
Weighing the two main options? See shingles vs. metal in North Texas.
Tile, slate and wood: what to know before you fall for the look
Our Prosper page notes that synthetic slate, tile and standing-seam metal all show up on area homes. They can last a long time, but they change the structural math. InterNACHI's tile-inspection course book (PDF) gives standard clay tile at about 600 to 650 pounds per roofing square (100 square feet), concrete tile at about 800 to 1,100 pounds, and lightweight concrete at about 500 to 800. The Tile Roofing Institute installation manual says to get the exact weight for a specific tile from the manufacturer and to count underlayment, fasteners and trim too.
- Structure first. R908.2 says the roof structure must support the new covering and the materials and equipment loaded on it during installation. Ask whether an engineer's letter is part of the quote when converting from shingles.
- Deck and fasteners. Tile goes on wood structural panels or solid sheathing (R905.3.1) with corrosion-resistant nails at least 11-gauge (R905.3.7).
- Walking the roof. The InterNACHI course warns that older tiles can be fragile and easily broken by attempts to walk on them. That affects how future repairs, inspections and rooftop equipment service are done.
- Reuse. Existing slate, clay or cement tile may be reinstalled during a re-roof, but damaged, cracked or broken pieces may not (R908.5).
- Wood shingles and shakes need 3:12 or steeper (R905.7.2, R905.8.2). Where a fire-rated roof is required, fire-retardant-treated wood must be pressure treated and labeled with its class (R902.2).
Underlayment: felt, synthetic and self-adhered
Shingles get the attention, but underlayment, flashing, and attic ventilation determine whether a roof lasts. Underlayment for asphalt shingles must meet one of the ASTM standards listed in the code and carry a label showing it (R905.1.1). For Celina heat and airflow details, read attic ventilation for North Texas.
| Underlayment type | Standard named in Table R905.1.1(1) | Notes |
|---|---|---|
| Asphalt-saturated felt | ASTM D226 Type I or II; ASTM D4869 Type I–IV | Traditional; where wind design is required, the table narrows shingle roofs to D226 Type II or D4869 Type III or IV |
| Synthetic underlayment | ASTM D8257 | Listed for asphalt shingles, clay and concrete tile, metal shingles, slate and solar (BIPV) coverings; not listed for wood shingles or shakes |
| Self-adhered polymer-modified bitumen | ASTM D1970 | A single layer is an allowed alternative to the layered felt method on shingle roofs when installed per the underlayment and shingle makers (Table R905.1.1(2)); also used as ice barrier |
| Other listed types | ASTM D6757 (shingles); ASTM D2626 and D6380 Class M (tile) | Check the label against the covering being installed |
On ice barriers: the code requires one only where the average daily temperature in January is 25°F or less (R905.1.2). The National Weather Service's Dallas-Fort Worth climate narrative describes local winters as generally mild, so the rule is not normally triggered here. That does not stop a manufacturer or roofer from specifying self-adhered membrane in valleys, at eaves or around penetrations, which is worth asking about. On a re-roof, an existing adhered membrane may sometimes stay in place under specific conditions (R908.3 exceptions).
Flashing and the other "soft metals"
Roofers call the thin metal parts of a roof the soft metals: gutters and downspouts, drip edge, valley metal, step and counter-flashing, vent caps, and pipe flashings. They matter twice. First, they are where most leaks start, because they seal the joints shingles can't. Second, they dent before shingles do, so dented gutters, vent caps and downspouts are one of the first things to photograph after hail (see our hail season guide and storm damage roof repair page).
What the 2024 IRC sets for shingle roofs:
- Metal flashing thickness. Where flashing is metal, it must be corrosion resistant and at least 0.019 inch thick, which the code equates to No. 26 galvanized sheet (R903.2.1). Base and cap flashing have the same 0.019-inch minimum (R905.2.8.1).
- Where flashing goes. At wall and roof intersections, wherever the roof changes slope or direction, around roof openings, and a diverter where an eave meets a sidewall (R903.2.1). That last one, often called kick-out flashing, keeps roof water out of the wall; our gutters and water intrusion guide shows what happens without it.
- Sidewall flashing. Continuous or step flashing at least 4 inches high and 4 inches wide, directing water away from the wall (R905.2.8.3).
- Valleys. Open metal valleys need lining at least 24 inches wide, in a metal from the code's table, such as 26-gauge G90 galvanized steel or 0.024-inch aluminum (R905.2.8.2).
- Drip edge. Required at eaves and rakes, lapped at least 2 inches and nailed no more than 12 inches apart (R905.2.8.5).
- Chimneys and wide penetrations. A cricket is required behind any chimney or penetration more than 30 inches wide (R903.2.2). Details in our chimney flashing and cricket guide; skylights are covered in the skylight leak guide.
- Reuse rules. On a re-roof, existing flashings, edgings, outlets and vents must be replaced where rusted, damaged or deteriorated (R908.5), and flashings are reconstructed per the manufacturer's instructions (R908.6).
Nails and fasteners
Nails are cheap, and that is why they get skimped. For asphalt shingles the 2024 IRC calls for galvanized steel, stainless steel, aluminum or copper roofing nails with at least a 12-gauge (0.105-inch) shank and a 3/8-inch head, complying with ASTM F1667. They must be long enough to go through the roofing and at least 3/4 inch into the sheathing, or all the way through sheathing thinner than that (R905.2.5). Each strip shingle needs at least four nails, or more if the manufacturer requires it (R905.2.6). Some manufacturers specify more nails for high-wind installations, so ask which pattern the quote is based on.
What about coastal rules? Some fastener rules in the code, like the stainless-steel requirement for wood shingle and shake fasteners, only apply within 15 miles of saltwater coastal areas (R905.7.6). Celina is far inland, so those don't apply here. Inland roofs still need corrosion-resistant nails and metal, and the fasteners need to be compatible with the metal they touch.
Color, heat and "cool" roofing
Celina summers are long and sunny, so color is not only an HOA question. The U.S. Department of Energy's Guidelines for Selecting Cool Roofs says most dark roof materials reflect 5 to 20% of sunlight, while light-colored materials typically reflect 55 to 90%. The same guide notes that cool asphalt shingles use specially coated granules, and that coating existing asphalt shingles is not normally recommended or approved by shingle manufacturers and may void the warranty. In other words, if you want a cooler shingle roof, the time to choose it is at replacement.
- Look up ratings. The Cool Roof Rating Council keeps a rated roof products directory with solar reflectance and thermal emittance values for listed products.
- Steep-slope rules are looser. The DOE guide explains that cool-roof thresholds for steep-slope roofs (most houses) are less strict than for flat commercial roofs.
- Check the HOA first. Many Celina-area HOAs approve specific colors. See HOA roofing guidelines before you pick a light shingle.
- Pair it with the attic. Color helps less if the attic is poorly vented or under-insulated. The attic ventilation guide compares the options.
Re-roofing: tear-off, recover and what can be reused
| Situation | What the 2024 IRC says |
|---|---|
| Full replacement | Removes existing layers down to the roof deck (R908.3), with limited exceptions for adhered membranes on sound sheathing |
| Recover (new roof over old) | Allowed only in listed cases (R908.4); not allowed when the existing roof is water soaked or deteriorated, is slate, clay, cement or asbestos-cement tile, or already has two or more layers |
| Standing-seam metal over an existing roof | Complete systems that carry loads straight to the structure do not require removing existing coverings (R908.4) |
| Metal or tile over old wood shakes | Allowed under R908.4; where it creates a combustible concealed space, the old surface must first be covered with gypsum board, mineral fiber, glass fiber or other approved materials (R908.4.1) |
| Reusing tile or slate | Allowed except damaged, cracked or broken pieces (R908.5) |
| Reusing flashing and vents | Must be replaced where rusted, damaged or deteriorated (R908.5) |
A tear-off also gives the roofer a look at the decking, which a recover hides. When comparing quotes, make sure both are priced the same way. For the decision between repairing and replacing after a storm, see repair vs. replace after a Collin County storm.
Where the old roof goes
Tear-off waste adds up. In the EPA's 2015 construction and demolition debris report, about 13.5 million tons of asphalt shingles were generated in the United States, and about 11.5 million tons of that (roughly 85%) went to landfills; most of the rest went into new products such as asphalt paving. Whether recycling is available depends on local processors, so it is fair to ask a roofer where the tear-off goes and whether disposal is included in the price.
Material choice checklist for a Celina home
- Measure the slope of every section, including porches and patio covers. It may rule some materials out (2:12 shingles, 2.5:12 tile, 3:12 wood or metal shingles, 4:12 slate).
- Get HOA approval for color and profile before ordering.
- Confirm the design wind speed with the roofer or permit office and pick a shingle wind class that meets or exceeds it.
- Decide on hail protection: Class 4 label, IBHS rating, or both. Look at the hail-size table above for context.
- Ask your insurance agent what discounts and exclusions apply to the exact product, before you sign.
- For tile or slate, get a structural check of the framing in writing.
- Specify the layers: underlayment product and standard, where self-adhered membrane goes, and which metal is new.
- Think about heat: lighter colors and a balanced attic vent plan help through a Collin County summer.
- Keep the paperwork: product names, colors, wind and impact classes, and the warranty registration. They matter for future claims and resale.
Questions to ask about materials in a quote
- Which shingle product and color, and what wind and impact classifications does it carry? Is it in the IBHS ratings, and how did it score?
- What underlayment (product and ASTM standard), and where will ice-and-water or self-adhered membrane go (valleys, eaves, penetrations)?
- Which metal is new and which is reused: drip edge, valley metal, step flashing, counter-flashing, pipe flashings, vent caps?
- What gauge or thickness and coating is the new flashing?
- What nails, and how many per shingle? Is that the manufacturer's standard or high-wind pattern?
- Is this a full tear-off to the deck, and how is replacement decking priced?
- For tile, slate or a heavier product: who checks the framing, and is that in the price?
- Where does the tear-off go, and is disposal included?
- Does the installation qualify for the manufacturer's enhanced warranty? (Our roofing warranties guide explains the tiers.)
For the rest of the scope, including permits, tear-off and inspections, see roof replacement in Celina, our roof replacement cost guide, and how to hire a roofer in Celina. Buying a home? The home buyer roof inspection guide lists what to ask about the existing materials.
Frequently asked questions
What nails should a roofer use on asphalt shingles?
The 2024 International Residential Code, which Celina enforces, calls for galvanized steel, stainless steel, aluminum or copper roofing nails with at least a 12-gauge (0.105-inch) shank and a 3/8-inch head, complying with ASTM F1667, long enough to go at least 3/4 inch into the roof sheathing or all the way through thinner sheathing. It also requires at least four nails per strip shingle, or more if the manufacturer says so.
What are the "soft metals" on a roof?
The thin metal parts: gutters and downspouts, drip edge, valley metal, step and counter-flashing, vent caps, and pipe flashings. They dent more easily than shingles, so dents in them are one of the first things to photograph after hail. Code also sets minimum thicknesses for some of them, such as 26-gauge galvanized steel (0.019 inch) for metal flashing.
Should old flashing be reused on a new roof?
Only if it is in good shape. The 2024 IRC says existing flashings, edgings, outlets, vents and similar parts must be replaced where they are rusted, damaged or deteriorated during a re-roof, and that flashings are to be reconstructed per the manufacturer's instructions. Ask the roofer to say in writing which metal is new and which is reused.
Do coastal stainless-steel nail rules apply in Celina?
No. The code's stainless-steel fastener rule for wood shingles and shakes applies within 15 miles of saltwater coastal areas, and Celina is far inland. Inland homes still need corrosion-resistant fasteners and flashing, and fasteners must be compatible with the roofing metal.
Can I switch my Celina house from shingles to tile?
Maybe, but weight comes first. An InterNACHI tile course puts standard clay tile at about 600 to 650 pounds per roofing square (100 square feet) and concrete tile at about 800 to 1,100 pounds per square, and the Tile Roofing Institute manual says to get the exact weight from the tile maker. The 2024 IRC (R908.2) says the roof structure must be able to carry the new roof covering, so most shingle-to-tile conversions need the framing checked by an engineer first. Tile also needs a slope of at least 2.5 in 12, with double underlayment up to 4 in 12.
Is synthetic underlayment allowed under shingles?
Yes. For asphalt shingles, Table R905.1.1(1) of the 2024 IRC lists felt (ASTM D226 or D4869), self-adhered membrane (ASTM D1970), ASTM D6757 and synthetic underlayment (ASTM D8257). Whatever is used must carry a label showing the standard. Ask which product and standard your quote is based on.
Does code require ice-and-water shield on a Celina roof?
The code ice-barrier rule (R905.1.2) applies where the average daily temperature in January is 25 degrees F or less, and the National Weather Service describes Dallas-Fort Worth winters as generally mild, so the rule is not normally triggered here. Manufacturers and roofers may still use self-adhered membrane in valleys, at eaves or around penetrations. Ask where it will go, and let the city inspector decide what your permit needs.
Can a new roof go over my old shingles?
Sometimes. Model 2024 IRC R908.4 allows a recover in limited cases, but not when the existing roof is water soaked or deteriorated, when it is slate, clay, cement or asbestos-cement tile, or when there are already two or more layers. A full replacement (R908.3) means removing the old layers down to the deck, which also lets the roofer see the decking. Celina's inspector has the final word.
What wind rating should my shingles have?
The 2024 IRC requires shingles to be tested to ASTM D7158 (or D3161 if outside D7158's scope) and labeled with a class that matches the design wind speed. For design wind speeds up to 116 mph, D7158 Class D, G or H or D3161 Class A, D or F qualifies; higher speeds need G or H (or F). The IBHS FORTIFIED Roof program asks for the top ratings, D3161 Class F or D7158 Class H. Ask your roofer and the city which design wind speed applies to your address.
Which roofing material handles hail best?
No material is hail-proof. In its November 2025 ratings IBHS tested 24 impact-resistant asphalt shingles bought at retail; most rated Good, none rated Excellent, and IBHS does not recommend Marginal or Poor products where hail is common. Metal is tough but can still dent, and the Texas Department of Insurance notes that metal-roof discounts can come with cosmetic-damage exclusions. Compare the specific product rating, not just the material name.
How a free quote request works
Our guides present options with honest tradeoffs for Celina-area weather, not a single "premium upsell." Celina Roof Pros is a free homeowner resource and referral service, not a roofing contractor, and we do not sell or install materials. If you fill out the quote form, we send your request to one independent local roofer who covers your town. That roofer contacts you, looks at the roof, and quotes in writing under their own business. There is no fee from us and no obligation to hire anyone. Mention the material you are considering in the form so the roofer can plan.
Serving Celina, Prosper, Anna, Melissa and Princeton. Related: roof replacement · roof repair · roof inspection · storm and hail damage · all guides
Sources
All accessed November 10, 2026, except where noted.
- ICC: 2024 International Residential Code, Chapter 9 Roof Assemblies (text checked via UpCodes: R902.1–R902.4, R903.2.1, R903.2.2, R904.2, R905.1.1 and Tables R905.1.1(1)–(2), R905.1.2, R905.2.1–R905.2.8.5 and Table R905.2.4.1, R905.3.1–R905.3.7, R905.4.2, R905.6.2–R905.6.6, R905.7.2, R905.7.6, R905.8.2, R905.10.2–R905.10.4, R905.16, R908.2–R908.6)
- City of Celina: Building Services (adopted 2024 International Codes) (blocks automated checks; last verified October 30, 2026)
- IBHS: Hail Impact-Resistant Shingle Ratings and November 19, 2025 ratings release
- IIBEC Interface: Testing of Impact-Resistant Asphalt Shingles (May 2020)
- FORTIFIED (an IBHS program): FORTIFIED Roof
- Texas Department of Insurance: Metal roofs and home insurance, 4 key facts (August 10, 2026)
- InterNACHI: Inspecting Tile Roofs, student course book (PDF)
- Tile Roofing Institute: Concrete and Clay Roof Tile Installation Manual (PDF)
- U.S. Department of Energy: Guidelines for Selecting Cool Roofs (PDF, via Lawrence Berkeley National Laboratory)
- Cool Roof Rating Council: Product Directories
- U.S. EPA: Construction and Demolition Debris Management in the United States, 2015 (PDF, March 2020)
- National Weather Service Fort Worth: Dallas/Fort Worth Climate Narrative
- NOAA Storm Prediction Center severe weather reports (2005–2024, within 10 miles of each town center)
Educational only. Not code, engineering or insurance advice. Celina Roof Pros is not a roofing contractor and does not inspect, install or warranty roofs; the independent roofer you may be referred to works under their own business. Confirm code requirements with your city and product requirements with the manufacturer.