A chimney is one of the biggest holes in a roof. InterNACHI's roof inspection series puts it plainly: the point where the chimney penetrates the roof "is basically a big hole in the roof," and no matter what the chimney is made of, that opening has to be sealed with flashing. Left long enough, metal flashing corrodes and leaks; installed incorrectly, it can leak right away.
Below: how chimney flashing is supposed to be layered, what a cricket is and when the code calls for one, the shortcuts that cause most leaks, framed chases with metal tops, clues you can check from the ground and the attic, hail and re-roof points, and who to call. Sources are listed at the bottom. No prices are quoted, because the honest answer depends on what actually failed.
The layers that keep a chimney dry
The U.S. Department of Energy's Building Science Education page on waterproofing chimneys calls the chimney "one of the largest penetrations in a residential roof assembly" and describes the metal flashing as three elements working together:
- Base (apron) flashing on the downhill face, which laps over the shingles below so water steps down onto the roof.
- Step flashing along the sides: short, overlapping pieces woven into each shingle course. InterNACHI's sidewall flashing article says all shingle manufacturers require step flashing at sidewalls, and that continuous one-piece flashing used with shingles is a defective installation.
- Counter-flashing set into the brick or stone that laps down over the base and step flashing, so water running down the chimney face cannot get behind them. InterNACHI's counter-flashing article describes the correct method on brick: sections inserted into the mortar joints (or a groove cut into the brick), then sealed.
The rule underneath all of it, from InterNACHI's asphalt shingle flashing article: on the uphill side the flashing is overlapped by the roofing, and on the downhill side the flashing overlaps the roofing. Water should always be stepping down onto the next layer, never running behind it. The uphill side of a chimney is where that gets hard, which is why crickets exist.
What a chimney cricket does
A cricket (or saddle) is a small peaked roof built on the uphill side of the chimney. InterNACHI's chimney inspection article describes it as "a small roof designed to keep runoff from pooling on the uphill side of the chimney." Without one, everything that runs down the slope above a wide chimney, including rain, leaves, and grit, piles into a flat pocket against the brick and sits there.
The model building code sets a size trigger. Section R903.2.2 of the International Residential Code (2024 edition text, as published on UpCodes; the official ICC chapter 9 is the reference) says a cricket or saddle "shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope," and that its covering must be sheet metal or the same material as the roof. The one exception is for unit skylights flashed to the manufacturer's instructions.
The City of Celina's Building Services page lists the 2024 International Codes, including the IRC, as its adopted codes effective January 2026. Cities adopt codes with local amendments, so if the exact requirement matters for your project, ask the City's permit desk or have your roofer confirm it.
Points worth knowing about crickets:
- A cricket makes two little valleys. InterNACHI notes that framing a cricket creates a couple of small valleys that have to be flashed correctly. Those valleys, and the joint where the cricket meets the chimney, are leak points of their own.
- Debris speeds up corrosion. The same article shows cricket valley flashing with corrosion and packed debris, and says debris holds moisture against the metal, so corrosion advances faster there. Overhanging trees make this worse.
- A missing cricket is reportable. InterNACHI tells inspectors that when a chimney that should have a cricket doesn't, they should say so in the report and explain why crickets are a good idea.
- Narrow chimneys are not exempt from leaks. Under 30 inches the code does not require a cricket, but the uphill flashing (sometimes called the back pan or head flashing) still has to direct water around the chimney. Ask what is installed there.
The shortcuts behind most chimney leaks
InterNACHI's chimney flashing article says brick and stone chimneys have the same problem as brick and stone walls: getting the counter-flashing right. It explains that because counter-flashing on brick and stone is so often done with sealant only, "the incorrect practice has become what's normal." Common conditions to ask about:
- Sealant-only counter-flashing. Metal stuck or caulked to the face of the brick instead of set into a mortar joint or cut groove. InterNACHI says sealant eventually dries, shrinks, and cracks and should be checked every year and re-applied as needed.
- Gaps in the mortar joints. The counter-flashing article shows flashing set into joints that were never properly filled, and flashing that was neither sealed nor fastened, leaving a path for water behind it.
- Missing counter-flashing. InterNACHI's example of it "just missing" leaves the top edge of the step flashing open to every rain.
- Continuous flashing on the sides in place of step flashing on a shingle roof.
- Stone chimneys "flashed" with gobs of sealant. InterNACHI says this is how stone sidewalls are most often done, even though the correct method extends counter-flashing up behind the stone.
If a contractor's plan for a leaking chimney is "we'll caulk it," ask what is under the sealant and whether the step and counter-flashing are actually there. Our guide to hiring a roofer in Celina covers the paperwork and questions to ask.
It is not always the flashing
The Chimney Safety Institute of America (CSIA) says water causes more damage to masonry chimneys than fire, and that it usually happens slowly enough to be ignored until the problem is serious. Its four prevention points cover more than the roof joint:
- Chimney cap to keep rain (and birds and animals) out of the flue.
- Crown in good repair. CSIA says crowns should project beyond all sides by two inches to protect the brick and mortar below.
- Flashing, the seal between the roofing and the chimney.
- Waterproofing the masonry. CSIA notes that common brick acts like a sponge, and defective mortar joints make it worse.
That is why a stain near the chimney sometimes needs two trades: a roofer for the flashing and cricket, and a chimney professional for the cap, crown, flue, and masonry. InterNACHI's chimney articles also cover cracked mortar caps, which it recommends sealing and checking every year.
Framed chases with metal tops
Not every "chimney" is brick all the way down. Factory-built fireplaces often vent through a framed chase, clad in siding, stone, or brick veneer, with a sheet-metal chase pan (chase cover) on top. CSIA's Level 2 inspection guide for factory-built fireplaces tells sweeps to inspect the storm collar, rain cap, and flashing; to look for rust, low spots, or pinholes that let water sit on the chase pan; to inspect any cricket; and, if the chase is wider than 30 inches and does not intersect the ridge, to recommend a cricket.
The practical takeaway: on a framed chase, water can come in through the top (a rusted or sagging pan), through the siding or veneer on the chase walls, or at the roof joint. A roofer can speak to the roof joint and cricket; the top of the chase and the venting are usually chimney or fireplace work.
Clues to check before you call
Stay off the roof. From the ground, binoculars and photos go a long way. From inside:
- Where the stain is. Ceiling or wall stains beside the fireplace, or on the ceiling just downhill of the chimney, point toward the roof joint. Water inside the firebox or a rusty damper can point more toward the cap, crown, or flue (CSIA lists rusted dampers among the results of chimney water penetration).
- When it happens. Note the date, how hard it rained, and which way the wind blew. A chimney that leaks only in wind-driven rain from one direction is a strong clue for whoever inspects it.
- The attic. CSIA's Level 2 masonry chimney guide tells inspectors to look for water damage "especially just below the flashing." If you can safely see the chimney from the attic, look for dark or stained sheathing and framing around it. InterNACHI also suggests checking around sealant-dependent flashing from the attic.
- What you can see from the ground. Shiny caulk lines or roof cement smeared on the brick, flashing pulled away from the chimney, rust on a metal chase top, or a flat, debris-filled pocket on the uphill side of a wide chimney.
- White staining on brick. InterNACHI notes that white efflorescence on brick and mortar is caused by moisture (in its example, flue condensation) and that over time it can deteriorate a chimney. Mention it if you see it.
If water is actively coming in, limit damage inside and see our emergency roof tarp guide for safe first steps while you wait for a roofer.
Hail, wind, and chimneys in Collin County
North Collin County gets regular large-hail days (see our Celina hail season guide and the NOAA-based hail history page). After a storm, look from the ground at the chimney cap, any metal chase top, and the flashing for dents, displacement, or bent metal, and photograph what you see. A leak that starts right after a storm is worth documenting separately from an old, slow stain.
The Texas Department of Insurance advises taking pictures and video of the damage, preventing more damage, and saving all receipts because your policy may pay for temporary repairs. Whether chimney or flashing damage is covered is between you and your insurer. We do not help with claims or speak to adjusters; our roof insurance claim tips page covers the general process.
Re-roofing? Settle the chimney details in writing
A re-roof is the natural time to fix chimney flashing and add a missing cricket, because the shingles around the chimney come off anyway. The IRC's re-roofing section (R908.5) says existing flashings that are part of the roof assembly "shall be replaced where rusted, damaged or deteriorated," and the asphalt shingle section (R905.2.8.4) says chimney flashing is applied according to the shingle manufacturer's instructions. The general flashing section (R903.2.1) calls for corrosion-resistant metal flashing no thinner than 0.019 inch (No. 26 galvanized sheet).
Questions to put to every bidder:
- Will you replace the step flashing, apron, and cricket flashing, or reuse it? Why?
- How will the counter-flashing be attached: set into mortar joints or a cut groove, or surface-mounted with sealant?
- Is the chimney more than 30 inches wide across the slope? If so, is there a cricket now, and will you build or re-flash one?
- Who handles the cap, crown, or chase top if those are part of the problem?
- Will you pull the City permit? Inside Celina city limits, the City's Building Services page says a Roof Permit is required for roofing projects, the general contractor must be registered with the City, and a $100 fee applies to each permit request.
Not sure whether a leak at the chimney justifies a full roof? Our repair vs. replace guide walks through age, damage spread, and matching. Skylights and chimneys share most of the same flashing logic; our skylight and flashing leaks guide covers the skylight side.
Who to call
- Roofer: leaks at the roof-chimney joint, missing or sealant-only flashing, a missing or failing cricket, hail-bent flashing, and any re-roof. Ask for a roof inspection or a roof repair quote.
- Chimney professional (sweep or mason): cap, crown, flue, spalling or cracked brick, mortar joints, waterproofing, and the chase top and storm collar on factory-built units. CSIA says annual chimney inspections and maintenance are best left to a qualified chimney professional.
- Both: when you can't tell where the water starts. Ask each to document what they found with photos.
Common questions
What is a chimney cricket and does my chimney need one?
A cricket (also called a saddle) is a small peaked roof built on the uphill side of a chimney so rain and debris split around the chimney instead of pooling against it. The model International Residential Code (R903.2.2) requires a cricket or saddle on the ridge side of any chimney or penetration more than 30 inches wide, measured perpendicular to the slope. Celina lists the 2024 IRC among its adopted codes; ask the City or your roofer about any local amendments.
Why does my chimney only leak during some storms?
Wind direction and how hard it rains both matter. Water driven against the uphill face or one side of a chimney can find a gap in step flashing, counter-flashing, or a cracked sealant joint that stays dry in light rain. Write down the date, how hard it rained, the wind direction, and where the stain appears each time; that log helps whoever inspects it narrow down the entry point.
Is caulk or roofing cement a real fix for chimney flashing?
Usually not a permanent one. InterNACHI explains that sealant eventually dries, shrinks, and cracks, and that counter-flashing relying on sealant alone needs ongoing maintenance and should be checked every year. Properly installed counter-flashing on brick is set into the mortar joints (or a cut groove) and then sealed. If a repair plan is only more caulk, ask what is underneath.
My house has a framed chimney with a metal top. Can that leak too?
Yes. Factory-built fireplaces often vent through a framed chase topped with a metal chase pan. The Chimney Safety Institute of America (CSIA) tells sweeps to check chase pans for rust, low spots, or pinholes that let water sit, and to recommend a cricket if the chase is wider than 30 inches and does not meet the ridge. A leak there may be the pan, the storm collar, the siding, or the roof flashing.
Should chimney flashing be replaced when I get a new roof?
Ask about it in every bid. The IRC re-roofing section (R908.5) says existing flashings that are part of the roof assembly shall be replaced where rusted, damaged, or deteriorated, and the shingle sections say chimney flashing goes on per the shingle manufacturer instructions. Inside Celina city limits a Roof Permit is required for roofing projects, pulled by a City-registered general contractor.
How Celina Roof Pros fits in
Celina Roof Pros is a free homeowner resource and quote-request service. We send each Celina-area homeowner’s request to one local roofer. We are not a roofing contractor and do not do inspections or repairs ourselves, and we never help with insurance claims or speak to adjusters. When you request a quote, mention the chimney, when the water shows up, which way the wind was blowing, and any photos you have, so the roofer comes ready to look at the flashing and cricket.
Request a free quote. Serving Celina, Prosper, Anna, Melissa and Princeton.
Sources
- InterNACHI: Mastering Roof Inspections, Roof Penetrations, Part 1 (Chimney flashing and counter-flashing)
- InterNACHI: Mastering Roof Inspections, Roof Penetrations, Part 2 (Cricket, cap, flue)
- InterNACHI: Mastering Roof Inspections, Flashing, Part 2 (Step flashing at sidewalls)
- InterNACHI: Mastering Roof Inspections, Flashing, Part 3 (Counter-flashing)
- InterNACHI: Mastering Roof Inspections, Asphalt Composition Shingles, Part 21 (Flashing at penetrations)
- ICC: 2024 International Residential Code, Chapter 9 Roof Assemblies
- UpCodes: IRC 2024 Chapter 9 text (R903.2.1, R903.2.2, R905.2.8.4, R908.5)
- U.S. Department of Energy, Building Science Education: Waterproofing Chimneys
- CSIA: Four Low-Cost Recommendations to Prevent Major Water Damage
- CSIA: Level 2 Inspection of a Masonry Chimney (PDF)
- CSIA: Level 2 Inspection of a Factory-Built Fireplace (PDF)
- City of Celina: Building Services (Roof Permit requirement; adopted 2024 codes)
- Texas Department of Insurance: After hail or windstorms
← All resources · Roof repair · Roof inspection · Skylight leaks · Request a quote