Skylight Leaks & Flashing Repairs in Celina, TX: Causes, Clues, and Who to Call

How skylights and their flashing keep water out, why they leak, what North Texas weather does to them, and how to tell a leak from condensation, for homeowners in Celina, Prosper, Anna, Melissa, and Princeton. Educational only. It is not an inspection, a repair estimate, or a contractor quote.

A skylight is a hole in the roof with glass in it. Everything that keeps it dry happens in a few inches of metal flashing, underlayment, and shingles around the frame. When a stain shows up on the ceiling of a skylight well, the cause is usually one of three things: the flashing, the skylight unit itself, or moisture inside the house condensing on cold glass.

Below: why skylights are leak-prone, what our local rain, wind and freeze records show, how the flashing is supposed to be built, what the building code says, clues you can check from inside, the condensation look-alike, hail, warranties, re-roofing and who to call. Sources are listed at the bottom with the date we checked them; no prices are quoted.

The short version

  • Look at the flashing first. Home inspectors list improper or incomplete flashing among common skylight installation problems, and treat sealant patches as evidence of an earlier leak, not a fix.
  • Our wet, windy season is spring. At McKinney National Airport, 41% of rain hours with strong wind fell in March–May (2005–2025). That is when weak flashing tends to show itself.
  • Winter water is often condensation. The airport averaged 348 hours a year at or below freezing, 89% of them in December–February. Cold glass plus humid indoor air makes water that looks like a leak.
  • Fog between the panes is a seal failure, not a roof leak. That goes to the skylight maker.
  • Re-roofing is the time to decide on each skylight: new flashing, a new unit, or removal. Get the answer in writing.
  • Stay off the roof. Check from the ground, from inside, and from the attic.

Why skylights leak more than windows

An American Society of Home Inspectors (ASHI) Reporter article on skylights explains that because skylights are not vertical, they are more exposed to rain, wind, and hail than windows, are more likely to catch and hold water, and see far more direct sunlight and UV. Its list of common problems includes:

  • Leaks, and the rot that long-term minor leakage causes, often hidden in the framing
  • Mechanical damage from falling branches or animals
  • Cracked or broken glazing from impact, structure movement, or thermal stress
  • Loss of seal on double-glazed units
  • Installation problems: no curb or a low curb, improper or incomplete flashing, a unit made for one roof type installed on another, a window used as a skylight, or a unit poorly secured to the roof
  • Patches, which the article calls a red flag, because they are evidence of a previous leak

The same article is blunt: "Most skylights leak eventually." It adds that leaking skylights can damage interior finishes and also cause rot and mold in concealed areas and damage the structure. That is not a reason to fear skylights. It is a reason to check them on purpose, especially when the roof is being repaired or replaced.

What Celina-area weather does to a skylight

Skylight problems tend to show up in particular weather: heavy rain, rain driven by strong wind, and cold snaps when humid indoor air meets cold glass. To see when that weather actually happens here, we went through 183,944 hours of automated weather observations from McKinney National Airport (KTKI), the closest long-running airport station to Celina, for 2005–2025. The observations come from the Iowa Environmental Mesonet's ASOS archive. Here is what we counted:

  • Rain hours: clock hours when the station reported rain or drizzle at least once. That averaged about 435 hours a year.
  • Heavy-rain hours: hours with a heavy-rain report (the "+" code). About 84 a year.
  • Wind-driven rain hours (our definition): rain reported along with sustained wind of about 20 mph or more (17 knots) or a gust of about 30 mph or more (26 knots). About 50 a year.
  • Freezing hours: hours when the temperature stayed at or below 32°F.
Average hours per year by month, McKinney National Airport (KTKI), 2005–2025
MonthRain hoursHeavy-rain hoursWind-driven rain hoursHours at or below 32°F
January 38.7 5.5 2.4 133.7
February 38.2 5.6 3.5 91
March 46 9 6.3 16.3
April 38.8 9.2 7.1 0.1
May 47.9 11 6.9 0
June 30.5 7 4.7 0
July 20.2 4 2.2 0
August 20.6 4 1.9 0
September 32.5 5.2 2.4 0
October 41.4 10.4 4.6 1
November 36.4 6.9 3.5 21.5
December 43.9 6.9 4.4 84.4

What stands out

  • May has the most rain hours (47.9 a year on average) and also the most heavy-rain hours (11). July and August are the driest by this count.
  • Wind-driven rain peaks in April (7.1 hours a year). March through May together average 20.3 hours, about 41% of the year's total, versus 4.1 for July and August combined.
  • Freezing is mostly a winter issue here. 89% of freezing hours fell in December, January and February. The station averaged 41.8 days a year with a low at or below 32°F, ranging from 26 (2020) to 62 (2022).
  • Ice does happen. The station reported freezing rain, freezing drizzle or ice pellets on 51 days over the 21 years, in 19 of those years.
  • February 2021 was the outlier. The longest stretch at or below freezing in the record ran about 237 hours (roughly 9.9 days), from February 9 to February 19, 2021.

Why this matters for skylights: ASHI notes that a skylight that is dry in one season may leak in another, and lists ice damming around skylights as a common cold-weather issue. VELUX's warranty summary excludes ice damming and condensation, and says condensation comes from indoor humidity or the difference between indoor and outdoor temperatures. So spring storms are when flashing problems tend to show, and the coldest weeks are when condensation is most likely to be mistaken for a leak.

Which way the wind-driven rain comes from

It can help to know which way that wind usually blows. Here is the wind direction during the wind-driven rain hours above (1,047 hours with a reported direction):

Wind direction (blowing from) during wind-driven rain hours, McKinney National Airport (KTKI), 2005–2025
FromHoursShare
North 302 29%
Northeast 59 6%
East 30 3%
Southeast 88 8%
South 217 21%
Southwest 47 4%
West 120 11%
Northwest 184 18%

North, south and northwest winds account for 67% of those hours, and easterly winds are rare. A practical way to use this: if a skylight stain only appears in certain storms, note the date and which way the wind was blowing. That points a roofer to the side of the curb or the run of step flashing to check first. Our wind damage guide covers the strongest gusts at the same station.

Data note: hourly counts come from the station's raw reports (main body only, standard time). Missing hours are not filled in (for the longest freezing stretch, gaps of up to two missing hours were bridged; any warmer hour ended it). These are airport readings, not measurements at your house, and the 20/30 mph cutoffs are our own definition for comparison, not an official threshold.

How skylight flashing is supposed to work

InterNACHI's roof flashing series defines flashing as sheet metal shaped to keep water out of the areas of a roof most likely to leak. It notes that the building code (IRC) does not dictate one flashing method; it requires flashing to be corrosion-resistant and installed so it prevents moisture entry. The 2024 IRC (R903.2.1) requires flashing "around roof openings," and says metal flashing must be corrosion resistant and at least 0.019 inch thick (No. 26 galvanized sheet).

The rule that applies to every penetration, per InterNACHI's asphalt shingle flashing article: on the uphill side the flashing is overlapped by the shingles, and on the downhill side the flashing overlaps the shingles. Water should always be stepping down onto the next layer, never running behind it.

InterNACHI's roof penetrations article lists a few key points that show installation quality:

  • Above the skylight: shingles should stop an inch or so short of the skylight to leave a channel for water to run around it.
  • Uphill corners: the flashing should extend past each corner by at least 1/8 inch.
  • Sides and bottom: the type of flashing depends on the roof covering.

On a shingle roof, the sides are a roof-to-wall joint in miniature. InterNACHI's sidewall flashing article says all shingle manufacturers require step flashing (short overlapping pieces woven into each course) at sidewalls, and that continuous one-piece flashing used with shingles is a defective installation "no matter how often you see it." The 2024 IRC (R905.2.8.3) sets base flashing at sidewalls at a minimum of 4 inches high and 4 inches wide, directing water away from the wall onto the roof.

One code detail is specific to skylights. Chimneys and other penetrations more than 30 inches wide need a cricket (a small diverter) on the uphill side under 2024 IRC R903.2.2, but unit skylights installed and flashed according to the manufacturer's instructions are exempt. In practice, that makes the manufacturer's flashing kit and instructions the standard to check against. Our chimney flashing and cricket guide covers crickets in detail.

Curb-mounted vs. deck-mounted (self-flashed) skylights

InterNACHI describes two common setups. Self-flashed skylights come from the factory with flanges that fit against the roof and use a flashing kit. Curb-mounted skylights sit on a site-built curb of 2x4 or 2x6 lumber on edge, with a flashing kit or hand-fabricated flashing. VELUX's skylight FAQ says its curb-mounted units are designed for low-pitch and flat roofs, fit pitches from flat to 20:12, and can also go on some standard-pitch roofs, while deck-mounted units sit lower, attach directly to the roof deck, and are listed for pitches from 3:12 (14 degrees) to 60 degrees.

ASHI's article ranks curb mounts as the best performers in its inspectors' experience, integral-curb units as fair, and flush mounts as the most leak-prone. It recommends curbs at least 4 inches high on sloped roofs (8 inches on flat roofs), flashed independently of the skylight, and treats a curb "like a short chimney": step flashing and counter-flashing on the sides, head flashing at the top, and an apron at the bottom, with self-adhering membrane running up the sides of the curb. One photo it uses shows a curb with step flashing but no counter-flashing and no self-adhering underlayment on the sides, leaving the wood exposed. InterNACHI's counter-flashing article explains that counter-flashing keeps water from getting behind the vertical leg of the step flashing.

Skylight mounting types at a glance (per ASHI, InterNACHI, VELUX and the 2024 IRC)
TypeHow it sitsWhere it fitsWhat to look for
Curb-mountedOn a raised wood curb; unit screws onto the curbFlat and low-slope roofs; some steeper roofsCurb at least 4 in. on sloped roofs (ASHI); step and counter-flashing on sides; head and apron flashing
Deck-mounted / self-flashedFlanges sit on the roof deck; uses a matched flashing kitPitched roofs (VELUX: 3:12 to 60°)The maker's flashing kit and underlayment collar, not sealant
Flush mountLittle or no raised frameVariesASHI rates these the most leak-prone; look closely for patches
Any unit on a roof under 3:12On a curb at least 4 in. above the roofLow-slope roofsRequired by 2024 IRC R324.6.8 unless the maker's instructions say otherwise

What the building code says about skylights

The 2024 International Residential Code has a section just for skylights and sloped glazing (R324.6). Cities adopt code editions and local amendments on their own schedules, so check which edition your city enforces. These are the parts a homeowner can actually use:

  • Glass types are limited. Skylight glazing must be laminated glass (with a minimum plastic interlayer), fully tempered glass, heat-strengthened glass, wired glass, or approved rigid plastics (R324.6.2).
  • Screens under some glass. When the inner pane is fully tempered, heat-strengthened or wired glass, a broken-glass retention screen is required under the full area of the glass, with exceptions for some smaller, lower tempered units (R324.6.3–R324.6.5). Laminated glass as the inner pane needs no screen. The screen must hold twice the weight of the glass, sit within 4 inches of it, and have openings no bigger than 1 inch by 1 inch (R324.6.7).
  • Curbs on low slopes. On roofs flatter than 3:12, unit skylights must sit on a curb at least 4 inches above the roof unless the manufacturer's instructions say otherwise (R324.6.8).
  • A label you can look for. Unit skylights and tubular daylighting devices must be tested by an approved independent lab and labeled with the maker, performance grade, and inspection agency, showing compliance with AAMA/WDMA/CSA 101/I.S.2/A440 (R324.6.9). If you are buying a replacement unit, ask to see that label or listing.
  • Re-roofing rules. During a re-roof, existing flashings, edgings, vents and similar parts must be replaced if rusted, damaged or deteriorated (R908.5), and flashings must be rebuilt following the approved manufacturer's instructions (R908.6).

ASHI makes a related point from the inspection side: watch for windows used as skylights, because windows are meant to be vertical, and many authorities require glass more than 15 degrees off vertical to be strengthened.

Roofing cement and caulk are not flashing

This is the most common shortcut. ASHI calls roofing cement or caulking on a skylight "a temporary repair at best." InterNACHI repeats the same warning across its flashing and penetration articles: sealant eventually dries, shrinks, and cracks, so every sealed joint is another place to leak. When sealant is standing in for missing flashing, InterNACHI's advice is to replace it with proper flashing, or inspect and re-apply sealant every year until you do.

If a contractor's whole plan for a leaking skylight is "we'll caulk it," ask what is underneath and whether the flashing itself is the problem. Our guide to hiring a roofer in Celina covers the questions and paperwork to ask for.

Leak or condensation? Check before you call

ASHI notes that condensation problems "often look like leaks." Many skylights have an interior tray around the perimeter that collects condensation, and those trays can leak or overflow. ASHI adds that sealed units should never have condensation between the panes, while vented and drained skylights will have some condensation from time to time. VELUX's help center says condensation on a skylight is usually caused by excess moisture in the room, not the skylight, because warm, moist air rises to the ceiling. It adds that new homes usually carry more moisture for the first few years and tend to dry out after that, which is worth knowing if your home is new construction. A dehumidifier, ventilation, and air circulation help.

The physics is simple. The National Fenestration Rating Council's consumer guide explains that condensation forms when the inside surface of the glass is colder than the indoor air, and that the NFRC label on certified new windows often shows a Condensation Resistance (CR) rating on a 1–100 scale, where higher means condensation is less likely. VELUX says Low-E insulated glass keeps the interior pane warmer, which lowers the chance of condensation, and that its skylights have a gasket system to drain condensation.

The EPA's guide to mold and moisture recommends keeping indoor humidity below 60 percent, ideally between 30 and 50 percent, and says a humidity meter is a small, inexpensive tool sold at many hardware stores. Its tips to cut condensation: lower humidity, run bathroom and kitchen exhaust fans, use air conditioning or a dehumidifier, and increase air movement. It also says that if wet materials are dried within 24–48 hours after a leak, in most cases mold will not grow, so act quickly either way.

Clues to note before anyone climbs on the roof:

  • When it happens. Drips during or right after rain point to a leak. Moisture on a cold morning with no rain points to condensation. Our weather table above shows when each is most likely here.
  • Which storms. If it only leaks in wind-driven rain, note the wind direction.
  • Where it shows up. ASHI suggests looking for stains at the bottom corners of the skylight opening and on the well finishes; a stepladder helps.
  • Fog between the panes. VELUX says clouding between the two panes means the inner seal has broken. That is a seal failure, not a roof leak.
  • Old patches outside. Visible caulk or roof cement around the frame means someone has already chased a leak there.
  • Attic and well. If you can safely see the skylight well from the attic, look for dark or damp framing. ASHI recommends checking skylights from above, below, and the attic, and notes that skylight wells should be insulated. Our attic ventilation guide covers what else to look for up there.
What you see, what it usually points to, and who handles it
What you seeUsually points toWho to call
Drips or a growing stain during or right after rainFlashing, underlayment, or the unit-to-roof jointRoofer
Stain only after windy storms from one directionFlashing on the side facing that windRoofer
Water on the glass on cold, dry morningsCondensation from indoor humidityStart with humidity and ventilation; HVAC pro if it keeps happening
Fog or film between the panesFailed seal in the glass unitSkylight maker or original installer
Crack or craze in the glass or domeImpact (hail, branches) or thermal stressSkylight maker, installer, or roofer
Water only when a venting skylight was openRain sensor or operator issueSkylight maker or installer
Drips from a tubular skylight's ceiling lensCondensation in the tube, or flashing at the roof domeInstaller or roofer

ASHI also warns that a dry ceiling is not proof of no leak: a spot that is dry in one season may be wet in another. Write down dates and weather and take photos. That record helps whoever inspects it.

Venting skylights and rain sensors

Some skylights open. VELUX says its solar-powered and electric venting skylights include rain sensors that close the skylight automatically. The solar models use a sensor that reacts to the sound of rain, and the electric models sense moisture. On steeper roofs, VELUX says the solar model's sensor can be shielded by the skylight sash, and an installer should move it to the top of the skylight. Its FAQ also explains how to close an electric skylight by hand if the power goes out while it is open.

If water came in only while a venting skylight was open, that is a control or sensor question for the maker or installer, not a flashing problem. VELUX's warranty summary lists a 5-year warranty on systems and controls, including rain sensors.

Tubular skylights (sun tunnels)

Tubular daylighting devices use a small dome on the roof and a reflective tube down to a ceiling lens. VELUX describes its Sun Tunnel skylights as needing a smaller hole in the roof and no drywall finishing inside. They still go through the roof, so the dome's flashing matters the same way. The IRC's testing and labeling rule (R324.6.9) covers them too.

Water on the ceiling lens is not always a roof leak. VELUX's support guidance on condensation in sun tunnels says the tunnel does not make water. Moist air gets in through small gaps along the tube or its tape and then condenses. Its advice is to check the tube's full length and the taped joints and insulation wrap for gaps.

Hail and skylights

Hail is part of life in Collin County. NOAA Storm Prediction Center records show 34 days from 2005 to 2024 with hail an inch or larger reported within 10 miles of Celina's center. On 11 of those days the largest reported stone was 1.75 inches or more, and on 6 it was 2 inches or more. Our Celina hail history has the dated reports, and the hail season guide covers getting ready.

After a storm, look at skylight glazing from the ground or from inside: cracks, crazing on plastic domes, or a dented frame. ASHI notes that cracks in glazing are easy to miss, and that each pane of a double- or triple-glazed unit has to be checked. The code rules above matter here: a tempered inner pane generally needs a broken-glass screen under it, while a laminated inner pane does not, so it is worth knowing which glass your skylight has. Do not get on the roof yourself. If water is coming in, see our emergency roof tarp guide for safe first steps.

The Texas Department of Insurance advises taking photos and video of storm damage, preventing more damage by covering broken windows and holes to keep rain out, and saving receipts for temporary repairs. It also warns against paying in full up front and against signing contracts with blank spaces. We do not handle insurance matters. Our storm and hail page covers what a local roofer looks at after a storm.

Energy ratings, if you are replacing a skylight

A replacement skylight is also an energy decision. ENERGY STAR's criteria for windows, doors and skylights are based on NFRC-certified ratings and vary by climate zone. North Texas is in the South-Central zone on ENERGY STAR's map. For skylights in that zone, the current criteria table calls for:

ENERGY STAR skylight criteria, South-Central zone (October 2023 table)
RatingRequirementWhat it means
U-factor0.50 or lowerHow much heat passes through; lower insulates better
Solar heat gain coefficient (SHGC)0.25 or lowerHow much of the sun's heat gets in; lower blocks more summer heat
Air leakage0.3 cfm/ft² or lowerHow much air leaks through the unit

Orientation matters too. VELUX's FAQ says west-facing skylights bring in afternoon sun, south-facing ones bring bright light all day, and north-facing ones give steady, diffused light. It adds that a skylight's orientation is set by the roof slope it sits on.

Skylight warranties: what to check

Warranties vary by brand and model, so read the actual document for your unit. As one example, the VELUX warranty summary (posted May 28, 2026) lists a 20-year warranty on the seal between the glass panes, a 10-year warranty on the skylight and flashing for materials and workmanship, a 10-year hail warranty on laminated glass that requires the hailstorm to be confirmed by the National Weather Service, and 5-year warranties on systems and controls and on shades. Points that matter for a leak:

  • VELUX defines a leak as liquid water coming through the product, or between the product and the roof deck, caused by its installation. Condensation is excluded.
  • Claims are excluded when installation did not follow VELUX instructions, and for re-roofing without re-wrapping with VELUX adhesive underlayment and VELUX flashing.
  • Other listed exclusions include standing water that corrodes the glass, ice damming, neglecting maintenance, and extreme weather.
  • VELUX says not to attempt repairs or replacement without first contacting VELUX and getting written permission.
  • Claims start with the original installer, who has to verify the installation was done to VELUX instructions.
  • The warranty period is not reset or extended by a repair or replacement.

The VELUX FAQ also warns that adding a skylight means cutting into the roof and, if done improperly, may void a roofing warranty. Its advice: check your roofing contract, put your request in writing, and have the roofer coordinate (or flash in the skylight themselves). If your home is only a few years old, also read builder warranty vs. insurance after hail, and our roofing warranties guide covers how manufacturer and workmanship coverage differ.

Re-roofing? Decide about the skylights first

VELUX's FAQ says the best time to replace old skylights is when you re-roof, which saves time and money and lines up the skylight and roofing warranties. It puts the life of its skylights at 20 to 30 years and says a single skylight replacement typically takes a couple of hours. ASHI makes the same point from the inspection side: a failing skylight on a roof that needs replacement is a chance to replace both and then fix the interior. Old dome or bubble skylights that are discolored, show mildew stains, leak, or have condensation around the panes are the usual candidates, per VELUX.

Ask every bidder how they will handle each skylight, and get the answers in writing:

  1. Will each skylight be reused with new flashing, replaced, or removed and decked over?
  2. Whose flashing kit and underlayment will be used, and does that keep the skylight warranty in force?
  3. Will rusted, damaged or deteriorated flashing be replaced, as 2024 IRC R908.5 requires?
  4. On a curb-mounted unit, will the curb get step flashing, counter-flashing and self-adhering membrane up its sides?
  5. Who handles the interior finish if the skylight well is disturbed?
  6. Is a permit required for this work where you live, and who will pull it? VELUX notes that many states and municipalities require a building permit to install a skylight.

See our repair vs. replace guide, the roof replacement cost drivers, and the roof replacement page. In an HOA neighborhood, check whether skylight changes need review; our HOA roofing guide lists the questions to ask.

Safety: stay off the roof around skylights

Federal workplace safety rules (OSHA 29 CFR 1926.501(b)(4)) treat skylights as holes: construction workers must be protected from falling through them with covers, guardrails or personal fall arrest systems, and from stepping into or through them. If the rules require that much protection for trained crews, a homeowner should not be walking near a skylight. Do your checks from the ground with binoculars, from inside on a stepladder, and from the attic only if there is a safe walking path.

Simple upkeep that helps

  • Keep the uphill side clear. VELUX recommends clearing debris around the flashing so rainwater keeps flowing around the skylight, and suggests a leaf blower. That matches InterNACHI's point about leaving a water channel above the skylight.
  • Clean without climbing. VELUX says most window-cleaning companies can clean skylights with telescoping brushes and squeegees from the ground, and warns against abrasive or chemical cleaners on the glass.
  • Watch indoor humidity in winter, especially in bathrooms and kitchens, using the EPA's 30–50 percent target.
  • Look after big storms from the ground and inside, and photograph anything new.
  • Re-check old sealant patches yearly until the flashing is properly fixed, per InterNACHI.
A simple skylight log to share with a roofer
Write downWhy it helps
Date and time water appearedSeparates rain leaks from cold-morning condensation
Weather: rain, wind direction, temperaturePoints to the side of the skylight taking water
Where the stain or drip is (corner, side, glass)Narrows down flashing vs. glass vs. tray
Photos inside, outside from the ground, and in the atticShows change over time
Skylight brand, serial number, install yearNeeded for any manufacturer warranty claim

Who to call

  • Roofer: leaks during rain, missing or sealant-only flashing, step or counter-flashing problems, hail damage to the roof around the skylight, and any re-roof. Our roof repair page and roof inspection page explain what to expect.
  • Skylight manufacturer or original installer: fog between panes (seal failure), cracked glazing, rain sensor or operator problems, and warranty questions. Have the serial number ready.
  • HVAC or ventilation pro: condensation that keeps coming back with no rain, especially in bathrooms and kitchens

Buying a home with skylights? Add them to your walkthrough with our home-buyer roof inspection checklist. Stains near chimneys or roof-wall joints may be the same kind of flashing problem: see our chimney flashing and cricket leaks guide for chimneys, and gutters & water intrusion for kick-out flashing.

Frequently asked questions

Why does my skylight only leak in some storms?

Some leaks only show up when wind pushes rain against one side of the skylight. At McKinney National Airport, about 50 hours a year (2005–2025 average) had rain with sustained winds of 20 mph or more or gusts of 30 mph or more, and 41% of those hours fell in March, April and May. If a stain only shows up in certain storms, write down the date and the wind direction so a roofer knows which side of the skylight to look at first.

Is water on my skylight on a cold morning a leak?

Often it is condensation, not a leak. VELUX says condensation on skylights is usually caused by excess moisture in the room, because warm, moist air rises to the ceiling, and that new homes usually carry more moisture for their first few years. If the water shows up on cold, dry mornings and not during rain, start by lowering indoor humidity. The EPA recommends keeping it below 60 percent, ideally between 30 and 50 percent.

My skylight is foggy between the panes. Is my roof leaking?

No. VELUX says clouding or fogging between the panes means the seal between the glass has broken, which lets condensation form inside the glass unit. That is a skylight seal problem, not a roof leak. Find the serial number on the skylight and contact the manufacturer or original installer about the seal warranty.

Can a roofer just caulk around my skylight?

Caulk or roofing cement on a skylight is a temporary repair at best, according to the American Society of Home Inspectors. InterNACHI notes that sealant eventually dries, shrinks and cracks. If sealant is standing in for missing flashing, the lasting fix is proper flashing. Ask what is underneath before agreeing to a caulk-only repair.

Should I replace my skylights when I replace my roof?

It is usually the best time. VELUX says replacing old skylights during a re-roof saves time and money and lines up the skylight and roofing warranties, and its warranty excludes re-roofing without re-wrapping the skylight with its adhesive underlayment and flashing. The 2024 International Residential Code also says existing flashings that are rusted, damaged or deteriorated must be replaced during re-roofing. Ask each bidder, in writing, how they will handle every skylight.

Does a skylight need a curb?

On roofs flatter than 3:12, the 2024 International Residential Code requires unit skylights to sit on a curb at least 4 inches above the roof unless the manufacturer’s instructions say otherwise. On steeper roofs, deck-mounted skylights are common; VELUX lists its deck-mounted units for pitches from 3:12 (14 degrees) to 60 degrees. ASHI’s inspectors rate curb-mounted skylights as the best performers and flush mounts as the most leak-prone.

What kind of glass does code require in a skylight?

The 2024 International Residential Code limits skylight glazing to laminated glass, fully tempered glass, heat-strengthened glass, wired glass or approved rigid plastics. When the inner pane is tempered, heat-strengthened or wired glass, a broken-glass retention screen is generally required below it, with some exceptions for smaller, lower tempered units. Laminated glass used as the inner pane does not need a screen. Unit skylights also have to carry a label showing they were tested to AAMA/WDMA/CSA 101/I.S.2/A440.

Will a skylight hail warranty cover hail damage?

It depends on the brand and model, so read your own warranty. As one example, VELUX lists a 10-year hail warranty on its laminated glass skylights, and a claim requires showing the glass was broken by hail in a storm confirmed by the National Weather Service. Keep the storm date, photos and the skylight serial number together.

Is it safe to check my skylight from the roof?

We do not recommend it. Federal workplace safety rules treat skylights as holes in the roof that workers must be protected from falling through, using covers, guardrails or fall arrest. Check from the ground with binoculars, from inside, and from the attic if you can do so safely. VELUX notes that most window-cleaning companies can clean skylights with telescoping tools without getting on the roof.

How Celina Roof Pros fits in

Celina Roof Pros is a free homeowner resource and quote-request service. We send each Celina-area homeowner’s request to one independent local roofer, who contacts you and quotes in writing under their own business. We are not a roofing contractor, and we do not do inspections or repairs ourselves. There is no fee from us and no obligation. When you request a quote, mention the skylight, when the water shows up, and any photos you have, so the roofer comes ready to look at the flashing.

Request a free quote. Serving Celina, Prosper, Anna, Melissa and Princeton.

How we built this page

The weather tables come from raw hourly reports for McKinney National Airport (KTKI), 2005–2025, downloaded from the Iowa Environmental Mesonet and counted with a script; the hail day counts come from NOAA Storm Prediction Center report files. Building-code points are from the 2024 International Residential Code as published on UpCodes. Product details are manufacturer statements (VELUX is used as one widely sold example, not an endorsement). We do not quote prices.

Sources

All accessed November 13, 2026.

← All resources · Roof repair · Roof inspection · Storm & hail · Request a quote

Ready for a clear roofing plan?

Tell us about your roof in Celina or nearby. One local roofer calls you to inspect the roof, document conditions, and explain options. One call, no spam calls, and your info is never sold or shared.